SEDL / Journals / Journal of ASTM International (JAI) / Citation Page


Volume 3, Issue 3 (March 2006)

ISSN: 1546-962X
CODEN: JAIOAD
Published Online: 21 December 2005
Page Count: 9


Neutron and Photon Dosimetry at the LR-0 Reactor Using Paired Detectors

Fernandes, AC
Postdoctoral Fellow and Auxiliary Researcher, Reactor Sector, Nuclear and Technological InstituteUniversity of Lisbon Nuclear Physics Centre, SacavémLisbon,

Novák, E
Engineer and Senior Researcher, Nuclear Power and Safety Division, Nuclear Research Institute Řež plc., Řež u. Prahy,

Cardoso, J
Laboratory Head and Technician, Nuclear and Technological Institute, Sacavém,

Santos, L
Laboratory Head and Technician, Nuclear and Technological Institute, Sacavém,

Marques, JG
Postdoctoral Fellow and Auxiliary Researcher, Reactor Sector, Nuclear and Technological InstituteUniversity of Lisbon Nuclear Physics Centre, SacavémLisbon,

Rýpar, V
Engineer and Senior Researcher, Nuclear Power and Safety Division, Nuclear Research Institute Řež plc., Řež u. Prahy,

(Received 20 June 2005; accepted 29 September 2005)

Abstract

Paired thermoluminescence dosimeters and ionization chambers were used for characterizing mixed (neutron and photon) radiation fields at the LR-0, a zero power model of VVER reactors. Detector responses were investigated in standard photon and thermal neutron fields. A good agreement was obtained among the doses measured with the two methods. Furthermore, the measured photon and neutron attenuation values are consistent with those from evaluated, independent data.



Keywords:
reactor dosimetry, mixed fields, ionization chambers, thermoluminescence dosimeters

Paper ID: JAI13438
DOI: 10.1520/JAI13438
ASTM International is a member of CrossRef.

Author Title Neutron and Photon Dosimetry at the LR-0 Reactor Using Paired Detectors Symposium Reactor Dosimetry, 12th Volume, 2005-05-13 Committee E10