Journal Published Online: 13 July 2005
Volume 2, Issue 10

Corrosion of Modular Titanium Alloy Stems in Cementless Hip Replacement

CODEN: JAIOAD

Abstract

Severe, localized corrosion of titanium-alloy femoral stems has been reported for specific designs of hip prostheses intended for fixation using acrylic cement. The purpose of the present study was to examine the possibility that corrosion might also occur when titanium-alloy stems are inserted without cement, but the body of the stem is modular in design. Fourteen (7 primary and 7 revision) cementless, modular-body, titanium-6% aluminum-4% vanadium alloy femoral stems of similar design were removed at revision surgery after 2 to 108 months in situ. The reason for removal was unexplained pain (4), femoral or acetabular loosening (4), infection (3), recurrent dislocation (2), or component malposition (1). The devices and, in selected cases, tissue from the joint psuedocapsule were studied with the use of light and scanning electron microscopy. Fretting corrosion products were characterized using energy dispersive x-ray analysis, selected area diffraction, and micro-Raman spectroscopy. Damage at the modular body connections was absent in 3 stems, mild in 6, moderate in 4, and severe in 1. The surface damage was characterized predominately by fretting scars and by pitting and etching. Thick deposits of mixed titanium oxides were found adherent to the stem at the sites of corrosion and as 0.01 to 200 micrometer particles within histiocytes and multinucleated giant cells in the joint pseudocapsule. Fretting corrosion at the modular-body junctions of titanium-alloy femoral stems can generate solid degradation products, adding to the particulate burden of the periprosthetic tissues and potentially accelerating bearing-surface wear by a third-body mechanism. Both of these features can potentiate the development and progression of osteolysis. In addition, fretting corrosion can increase the potential for structural failure of the device. These findings stress the importance of the design of modular junctions to minimize corrosion and the generation of corrosion products.

Author Information

Urban, RM
Rush University Medical Center, Chicago, IL
Gilbert, JL
Syracuse University, Syracuse, NY
Jacobs, JJ
Rush University Medical Center, Chicago, IL
Pages: 10
Price: $25.00
Related
Reprints and Permissions
Reprints and copyright permissions can be requested through the
Copyright Clearance Center
Details
Stock #: JAI12810
ISSN: 1546-962X
DOI: 10.1520/JAI12810