Volume 8, Issue 2 (February 2011)

    Wear of a Mobile Bearing Uni-Compartmental Knee Replacement Prosthesis: A Comparison of In Vitro and In Vivo Wear Rates

    (Received 16 August 2010; accepted 12 January 2011)

    Published Online: 2011

    CODEN: JAIOAD

      Format Pages Price  
    PDF Version 6 $25   ADD TO CART


    Abstract

    Wear induced osteolysis is cited as the primary cause of aseptic loosening in knee replacements. It has been postulated that mobile bearing (MB) knee prostheses reduce wear as they allow lower contact stress through high congruency between components while maintaining a wide range of joint motion. In vitro wear simulations are preclinical tests for predicting the performance of new designs of partial and total knee replacements. This study investigates the wear of a leading design of MB uni-compartmental knee replacement (UKR) by quantifying the in vitro wear rate and linear penetration of the polyethylene meniscal bearing. Three medial and three lateral MB UKRs (Uniglide, Corin, Ltd., U.K.) were tested in a three station wear simulator using force control as defined in ISO 14243-1. Volumetric wear was determined gravimetrically every half million cycles (MC) up to 10 MC. Maximum linear penetration wear was measured after 10 MC. Volumetric wear rates of 1.65±0.28 mm3/MC (mean±SD) and 1.66±0.31 mm3/MC were recorded for the medial and lateral bearings, respectively, and the wear of all bearings was linear. Previous simulator studies have reported mean wear rates of 3.8 to 10.4 mm3/MC for MB UKRs. Maximum linear penetration wear rates of 0.013±0.001 mm/MC and 0.012±0.001 mm/MC were recorded for the medial and lateral bearings, respectively, after 10 MC. This was in agreement with that reported for well functioning MB UKRs through in vivo measurement (0.01 mm/year) and compared favourably to that reported for fixed bearing designs (0.15 mm/year). The results of this study show that in vitro measurements correlate well to in vivo measurements of wear. This indicates that the current in vitro methodology for the simulation of wear in MB UKRs is a valid tool for preclinical assessment of MB UKR prostheses.


    Author Information:

    Ellison, P. J.
    Corin, Ltd., Corinium Centre, Cirencester, Gloucestershire

    Traynor, A.
    Corin, Ltd., Corinium Centre, Cirencester, Gloucestershire

    Casey, B. P.
    Corin, Ltd., Corinium Centre, Cirencester, Gloucestershire

    Collins, S. N.
    Corin, Ltd., Corinium Centre, Cirencester, Gloucestershire


    Stock #: JAI103328

    ISSN: 1546-962X

    DOI: 10.1520/JAI103328

    ASTM International is a member of CrossRef.

    Author
    Title Wear of a Mobile Bearing Uni-Compartmental Knee Replacement Prosthesis: A Comparison of In Vitro and In Vivo Wear Rates
    Symposium Symposium on Mobile Bearing Total Knee Replacement Devices, 2010-05-18
    Committee F04