    Water Penetration of Cladding Components—Results from Laboratory Tests on Simulated Sealed Vertical and Horizontal Joints of Wall Cladding

    (Received 28 July 2008; accepted 8 April 2009)

    Published Online: 2009

    CODEN: JAIOAD

      Format Pages Price  
    PDF 21 $25   ADD TO CART


    Abstract

    Considerable work has focused on the deterioration of jointing compounds used to seal building joints; less emphasis has been placed on understanding the consequences of seal failure, particularly in respect to watertightness. Jointing products are subjected to different climate effects; some induce aging in the sealant that in time leads to deficiencies. Deficiencies may also come about from design faults or improper installation. Water entry at deficiencies may lead to a number of different deteriorating effects on the building fabric that may induce failure of other envelope components or premature failure of the joint sealant. Joints are also subjected to substantial wind driven rain loads, in particular atop multi-story buildings. The approach taken in this study focuses on determining the fault tolerance of joint systems of a simulated wall panel when subjected to watertightness tests that emulate heightened wind-driven rain loads. Vertical and horizontal joints of 20 mm width and sealed with a one-component polyurethane product were subjected to water spray rates ranging between 1.6 and 6 L/(min-m2) and pressures of up to 2 kPa. Faults introduced to the sealed joint and representative of deficiencies through which water could penetrate consisted of cracks of 2 to 16 mm long introduced along the sealant to substrate interface. For specific crack lengths, the crack size related to the degree of joint extension, the extension reaching a maximum of 10 % of joint width. Rates of water entry across the joint were determined for cracks of different lengths and size and the nature of water entry at deficient joints in which cracks were introduced was also examined. Results on vertical joints indicated that water readily enters open cracks in relation to the crack size, quantity of water present at the crack, and pressure across the opening. Water may also penetrate cracks of nonextended “closed” joints.


    Author Information:

    Lacasse, Michael A.
    Senior Research Officer, National Research Council Canada, Institute for Research in Construction, Ottawa,

    Miyauchi, Hiroyuki
    Assistant Professor, Department of Architectural Engineering, Chungnam National University, Daejeon,

    Hiemstra, J.
    Technical Assistant, National Research Council Canada, Institute for Research in Construction, Ottawa,


    Stock #: JAI102048

    ISSN: 1546-962X

    DOI: 10.1520/JAI102048

    ASTM International is a member of CrossRef.

    Author
    Title Water Penetration of Cladding Components—Results from Laboratory Tests on Simulated Sealed Vertical and Horizontal Joints of Wall Cladding
    Symposium Presented at the ASTM Third Symposium on Durability of Building and Construction Sealants and Adhesives, 2008-06-26
    Committee C24