Sensitivity Analysis and Neutron Fluence Adjustment for VVER-440 RPV
Belousov, SI
Senior Research Scientist, Institute for Nuclear Research and Nuclear Energy of Bulgarian Academy of Science,

Ilieva, KD
Senior Research Scientist, Institute for Nuclear Research and Nuclear Energy of Bulgarian Academy of Science,

Matushko, VL
Senior Research Scientist, Institute for Nuclear Research of Russian Academy of Science,

(Received 20 June 2005; accepted 25 January 2006)

Abstract

Adjustment of the neutron fluence on the VVER-440 reactor pressure vessel (RPV) inner wall has been carried out. For the purpose of this adjustment the neutron flux responses' sensitivity to the main parameters of calculation uncertainty has been calculated. The obtained sensitivities, the parameters uncertainty, and activity measurement data of iron, copper, and niobium detectors positioned behind the RPV of Kozloduy NPP Unit 1 have been used in this adjustment.



Keywords:
neutron fluence, adjustment, reactor pressure vessel

Paper ID: JAI13489
DOI: 10.1520/JAI13489
ASTM International is a member of CrossRef.

Author Title Sensitivity Analysis and Neutron Fluence Adjustment for VVER-440 RPV Symposium Reactor Dosimetry, 12th Volume, 2005-05-13 Committee E10