ASTM WK44465

    Revision of A847 / A847M - 12 Standard Specification for Cold-Formed Welded and Seamless High-Strength, Low-Alloy Structural Tubing with Improved Atmospheric Corrosion Resistance

    (What is a Work Item?)

    Active Standard: A847 / A847M - 14

    Developed by Subcommittee: A01.09 | Committee A01 | Contact Staff Manager



    WK44465

    1. Rationale

    In discussions during the last sub-committee meeting, the question has raised concerning whether the ERW weld should be allowed to be located in one of the corners in structural tubing. This point has just been addressed in A500 on a recent ballot. The consensus is that the weld should not be allowed in the corner unless requested by the purchaser. The wording used in the recent A500 ballot should be added to A847 under Section 5.2. The Summary of Changes was updated to reflect this change .


    Keywords


    Citing ASTM Standards
    Back to Top
    Work Item Status

    Date Initiated:
    12-18-2013

    Technical Contact:
    William Kirkland

    Item:
    032

    Ballot:
    A01 (14-02)

    Status:
    Ballot Item Approved as A847/A847M-2014 and Pending Publication