ASTM WK43904

    Work Item: ASTM WK43904 - Revision of A1073 / A1073M - 12 Standard Practice for Using Hand Micrometers to Measure the Thickness of Nonmetallic and Metallic-Coated Steel Sheet

    (What is a Work Item?)

    Active Standard: A1073 / A1073M - 14

    Developed by Subcommittee: A05.07 | Committee A05 | Contact Staff Manager



    1. Rationale

    Micrometers are used for measuring material thickness. Through much testing and statistical analysis, the Micrometer Accuracy has been determined. The Accuracy has been determined for Electronic Digital Micrometers to be +/- 0.0003 inches and for Vernier Micrometers to be +/- 0.0004 inches. For a copy of the draft Research Report, please contact Caitlin Farrell at cfarrell@astm.org


    Keywords

    micrometer; steel sheet; steel sheet – metallic-coated;
    Citing ASTM Standards
    Back to Top
    Work Item Status

    Date Initiated:
    11-01-2013

    Technical Contact:
    Herbert Koch

    Item:
    001

    Ballot:
    A05 (13-04)

    Status:
    Ballot Item Approved as A1073/A1073M-2014 and Pending Publication