1. Rationale
Section 5 (Significance and Use) references three alternative testing procedures for which neither a testing protocol nor endpoint/acceptance criteria is provided within E1529-10. One of these informational only procedures is provided as a text note (Note 1), differently than the others. The ballot item proposes changing Note 1 into new section 5.2.3: (1) for consistency with the other Section 5 alternative testing procedures within that section, and (2) because Note 1 includes an objectionable mandatory provision. (ASTMs Form and Style for ASTM Standards states: Notes in the text shall not include mandatory requirements.)
Keywords
fire test response; hydrocarbon pool fire; heat flux; temperature; thermal exposure; thermal shock; Beam test; Column tests; Fire-resistant materials/testing; Fire testing--building materials; Fire-test response; Fluid-hydrocarbon-fueled pool fires; Heat flux; Hydrocarbon pool fire; Hydrocarbon processing industry (HPI); Large hydrocarbon pool fire; Structural building materials/applications; Temperature tests--building materials; Thermal shock materials/testing; Walls;
Citing ASTM Standards
[Back to Top]