ASTM WK39458

    Work Item: ASTM WK39458 - Revision of D93 - 11 Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester

    (What is a Work Item?)

    Active Standard: D93 - 13e1

    Developed by Subcommittee: D02.08 | Committee D02 | Contact Staff Manager



    1. Rationale

    The maximum temperature of the test needs clarifying as it is not clear whether this is 360 C or 370 C


    Keywords

    automated flash point; automated Pensky-Martens closed cup; flammability; flash point; Pensky-Martens closed cup: Flammability--petroleum products; Flash point--liquids; Fuel oils; Liquids; Lubricating oils; Pensky-Martens closed cup tester; Solid phase materials; Suspension fluids; Thermometers; Viscous liquids/materials;
    Citing ASTM Standards
    Back to Top
    Work Item Status

    Date Initiated:
    10-23-2012

    Technical Contact:
    Mike Sherratt

    Status:
    Draft Under Development