Work Item: ASTM WK27356 - Revision of C173 / C173M - 09 Standard Test Method for Air Content of Freshly Mixed Concrete by the Volumetric Method


Active Standard: C173 / C173M - 10b

Developed by Subcommittee: C09.60 | Committee C09 Home | Contact Staff Manager



1. Rationale

The last sentence in Section 6.1 is addressed in Section 6 of ASTM C 172, therefore its inclusion in this standard is redundant. The sentence prior to the proposed deletion indicates that the wet sieving procedure is described in C 172. Section 6.2 is added to limit the material used for the volumetric air test to previously unused material. The consolidation process may adversely affect the air content of a concrete mixture. Thus, the reuse of material following a slump test, density test, or air content test by the pressure or volumetric method will not be permitted.


Keywords

air content; calibration; concrete; correction factor; freshly mixed concrete; measuring bowl; meter; volumetric method; Air content--concrete; Ready-mixed concrete--specifications; Volumetric measurement;

Citing ASTM Standards

[Back to Top]




Work Item Status:
Date Initiated:01-29-2010
Technical Contact: John Schemmel

Item: 002
Ballot: C09.60 (10-05)
Status: Withdrawn From Balloting

Item: 035
Ballot: C09 (10-03)
Status: Ballot Item Approved as C173/C173M-2010b and Pending Publication