Work Item: ASTM WK24692 - Revision of E648-09a Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source


Active Standard: E648-09a

Developed by Subcommittee: E05.22 | Committee E05 Home | Contact Staff Manager



1. Rationale

Item 1 - Section A2.2.1 states insert the cushion pad with the pattern side facing the carpet followed by a nominal 6.3-mm (14-in.) thick fiber-cement board having a density of 1442 160 kg/m3(90 10 lb/ft3) and meeting the requirements of Specification C 1186 Grade II and Test Method E 136 (Note X2.1) and a 13-mm (12-in.) 0.58 g/cm3 (36 lb/ft3) inorganic millboard. For this ballot, the intention is to include the use of inorganic millboard in in the Procedure section of the standard. Item 2 - At the June meeting in Vancouver, Ken McIntosh of the Carpet and Rug Institute requested that Section 9.2.1 be revised to include a cushion recommended by the manufacturer. This would make testing over a cushion consistent with instructions for selecting an adhesive for glue-down applications (Section A2.2.2) The adhesive shall be that recommended by the carpet manufacturer.


Keywords

critical radiant flux; fire; floor-covering systems; radiant panel; Critical radiant flux; Emittance; Fire testing--floors/flooring materials; Flaming ignition; Flammability--floors/flooring systems; Flooring/floor covering systems; Graded radiant heat energy; Heating tests--building products; Horizontally-mounted floor-covering systems; Radiant heat exposure/testing; Simulated concrete structural floor ; ICS Number Code 97.150 (Non-textile floor coverings)

Citing ASTM Standards

[Back to Top]




Work Item Status:
Date Initiated:06-22-2009
Technical Contact: Jonathan Jackson

Item: 004
Ballot: E05.22 (09-03)
Status: Negative Votes Need Resolution

Item: 005
Ballot: E05.22 (09-03)
Status: Negative Votes Need Resolution