Significance and Use
Use this test method to obtain a quantitative value indicating the rate of moisture vapor emission from a concrete floor and whether or not that floor is acceptable to receive resilient floor covering. The moisture vapor emission rate only reflects the condition of the concrete floor at the time of the test. All concrete subfloors emit some amount of moisture in vapor form. Concrete moisture emission is a natural process driven by environmental conditions. All floor coverings are susceptible to failure from excessive moisture vapor emissions. The moisture vapor emitted from a concrete slab is measured in pounds. This measurement is the equivalent weight of water evaporating from 1000 ft2 of concrete surface in a 24–h period. The calcium chloride moisture test has been the industry standard for making this determination and is a practical, well-established and accepted test of dynamic moisture. It will produce quantified results directly applicable to flooring manufacturer’specifications. The results obtained reflect only the condition of the concrete floor at that time.
1. Scope
1.1 This test method covers the quantitative determination of the rate of moisture vapor emitted from below-grade, on-grade, and above-grade (suspended) concrete floors.
1.2 This quantity of moisture shall be expressed as the rate of moisture vapor emission, measured in pounds of moisture over a 1000 ft2 area during a 24-h period.
1.3 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices, and determine the applicability of regulatory limitations prior to use.
2. Referenced Documents
C670 Practice for Preparing Precision and Bias Statements for Test Methods for Constsruction Materials
F141 Terminology Relating to Resilient Floor Coverings
Mil Spec B-131H Type 1, Class III
Recommended Work Practices
Index Terms
anhydrous calcium chloride; moisture vapor emission rate; quantitative calcium chloride; resilient flooring; RMA referee test; ICS Number Code 91.100.30
DOI: 10.1520/F1869-04

ASTM International is a member of CrossRef.
Citing ASTM Standards
[Back to Top]