Significance and Use
This practice provides minimum recommendations for the installation and preparation of wood-based, fiber-reinforced gypsum and fiber-cement panel underlayments suitable to receive resilient floor coverings. Actual requirements for materials to be used, mixtures, and other details are generally included as part of project plans or specification detail and may vary from the minimum recommendations set forth in this practice.
1. Scope
1.1 This practice includes recommendations for wood based, fiber reinforced gypsum and fiber-cement panel underlayment/subfloor assemblies upon which resilient flooring may be installed.
1.2 This practice does not cover the adequacy of the subfloor assembly to perform its structural requirements, which is governed by local building codes.
1.3 This practice does not supersede in any manner the resilient flooring, underlayment or adhesive manufacturer's written instructions. Consult the individual resilient flooring, underlayment or adhesive manufacturer for specific recommendations.
1.4 See Supplementary Requirements for "Select Warnings" that have been provided.
1.5 The values stated in inch/pound units are to be regarded as standard; the metric units in parentheses are for reference only.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
2. Referenced Documents
C1278/C 1278M Specification for Fiber-Reinforced Gypsum Panel
C1288 Specification for Discrete Non-Asbestos Fiber-Cement Interior Substrate Sheets
F141 Terminology Relating to Resilient Floor Coverings
ANSI/A208.1-1998 Particleboard
ANSI/AHA A135.4-1995 Basic Hardboard
APA Engineered Wood Construction Guide, Form E30
APA Installation and Preparation of Plywood Underlayment for Resilient Flooring, Form L335
Lead-Based Paint: Interim Guidelines for Hazard Identification and Abatement in Public and Indian housing (1991 revised)
Resilient Floor Covering Institute (RFCI) Recommended Work Practices for Removal of Resilient Floor Coverings (January 1998)
Voluntary Product Standard PS1-95 for Construction and Industrial Plywood
Voluntary Product Standard PS2-92 for Wood-Based Structural-Use Panels
Index Terms
fiber-cement; gypsum fiber; installation; OSB; particleboard; plywood; resilient; sheet; subfloor; tile; underlayment; vinyl; ICS Number Code 97.150
DOI: 10.1520/F1482-04

ASTM International is a member of CrossRef.
Citing ASTM Standards
[Back to Top]