Standards

ASTM E2088 - 06


ASTM E2088 - 06 Standard Practice for Selecting, Preparing, Exposing, and Analyzing Witness Surfaces for Measuring Particle Deposition in Cleanrooms and Associated Controlled Environments


Active Standard ASTM E2088 Developed by Subcommittee: E21.05 |Book of Standards Volume: 15.03

more info 5 pages $ 37.00
more info 5 pages $ 37.00
why redline? 10 pages $ 44.40

Historical(view previous versions of standard) ASTM License Agreement

Description Related Products

ASTM E2088

Significance and Use

This practice provides a standard approach to measuring particle deposition, or fallout, in cleanrooms and other controlled environments. It is based on the use of a witness surface to collect particles that deposit from the surrounding environment and subsequently sizing and counting the particles by conventional methods. Several options are introduced, with limitations and guidelines for selecting the best choice for the intended application.

This practice is applicable across numerous industries including aerospace, microelectronics, and pharmaceuticals.

1. Scope

1.1 This practice is intended to assist in the selection, preparation, exposure, and analysis of witness surfaces for the purpose of characterizing particle deposition rates in cleanrooms and associated controlled environments, particularly for aerospace applications.

1.2 Requirements may be defined in terms of particle size distribution and count, percent area coverage, or product performance criteria such as optical transmission or scatter. Several choices for witness surfaces are provided.

This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

1.3 The values stated in SI units are to be regarded as the standard.


2. Referenced Documents

E1216 Practice for Sampling for Particulate Contamination by Tape Lift
F24 Test Method for Measuring and Counting Particulate Contamination on Surfaces
F312 Test Methods for Microscopical Sizing and Counting Particles from Aerospace Fluids on Membrane Filters
Fed-Std-209 Airborne Particulate Cleanliness Classes in Cleanrooms and Clean Zones
IEST-STD-CC1246 Product Cleanliness Levels and Contamination Control Program
ISO 14644-1 Cleanrooms and Associated Controlled Environments-Part 1: Classification of Air Cleanliness


Index Terms

cleanroom; contamination control; controlled environment; ICS Number Code 13.040.35; 13.040.35