Standards

ASTM E1855 - 05e1


ASTM E1855 - 05e1 Standard Test Method for Use of 2N2222A Silicon Bipolar Transistors as Neutron Spectrum Sensors and Displacement Damage Monitors


Active Standard ASTM E1855 Developed by Subcommittee: E10.07 |Book of Standards Volume: 12.02

more info 10 pages $ 37.00
more info 10 pages $ 37.00
why redline? 20 pages $ 44.40

Historical(view previous versions of standard) ASTM License Agreement

Description Related Products

ASTM E1855

1. Scope

1.1 This test method covers the use of 2N2222A silicon bipolar transistors as dosimetry sensors in the determination of neutron energy spectra, and as silicon 1-MeV equivalent displacement damage fluence monitors.

1.2 The neutron displacement damage is especially valuable as a spectrum sensor in the range 0.1 to 2.0 MeV when fission foils are not available. It has been applied in the fluence range between 2 X 1012 n/cm2 and 1 X 1014 n/cm2 and should be useful up to 1015 n/cm2. This test method details the steps for the acquisition and use of silicon 1-MeV equivalent fluence information (in a manner similar to the use of activation foil data) for the determination of neutron spectra.

1.3 In addition, this sensor can provide important confirmation of neutron spectra determined with other sensors, and yields a direct measurement of the silicon 1-MeV fluence by the transfer technique.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory requirements prior to use.


2. Referenced Documents

E170 Terminology Relating to Radiation Measurements and Dosimetry
E1854 Practice for Ensuring Test Consistency in Neutron-Induced Displacement Damage of Electronic Parts
E2005 Guide for the Benchmark Testing of Reactor Dosimetry in Standard and Reference Neutron Fields
E261 Practice for Determining Neutron Fluence, Fluence Rate, and Spectra by Radioactivation Techniques
E265 Test Method for Measuring Reaction Rates and Fast-Neutron Fluences by Radioactivation of Sulfur-32
E720 Guide for Selection and Use of Neutron-Activation Foils for Determining Neutron Spectra Employed in Radiation-Hardness Testing of Electronics
E721 Guide for Determining Neutron Energy Spectra from Neutron Sensors for Radiation-Hardness Testing of Electronics
E722 Practice for Characterizing Neutron Energy Fluence Spectra in Terms of an Equivalent Monoenergetic Neutron Fluence for Radiation-Hardness Testing of Electronics
E844 Guide for Sensor Set Design and Irradiation for Reactor Surveillance, E706 (IIC)
E944 Practice for Application of Neutron Spectrum Adjustment Methods in Reactor Surveillance, (IIA)


Index Terms

displacement damage; neutron damage; radiation hardness; silicon transistors; spectrum sensors; ICS Number Code 31.200


DOI: 10.1520/E1855-05E01

ASTM International is a member of CrossRef.


Citing ASTM Standards

[Back to Top]

Standards Tracker

Standards Subscriptions