ASTM E1731 - 06 Standard Test Method for Gravimetric Determination of Nonvolatile Residue from Cleanroom Gloves


Active Standard ASTM E1731 Developed by Subcommittee: E21.05 |Book of Standards Volume: 15.03

more info 4 pages $ 32.00
more info 4 pages $ 32.00
why redline? 8 pages $ 38.40

Historical(view previous versions of standard) ASTM License Agreement

Description Related Products

ASTM E1731

Significance and Use

The NVR obtained by this test method is that amount which is available for release by the gloves onto handled surfaces.

Evaporation of solvent at the stated temperature is to quantify the NVR that can be expected to exist at room temperature, since the slight difference between room temperature and the test temperature is not likely to result in significant variances.

Various other methods exist for determining NVR, for example Practice G 120 and IES-RP-CC005.2. This test is not intended to replace test methods used for other purposes.

1. Scope

1.1 This test method covers the determination of solvent extractable nonvolatile residue (NVR) from gloves used in cleanrooms where spacecraft are assembled, cleaned, or tested.

1.2 The values stated in SI units are to be regarded as standard.

1.3 The NVR of interest is that which can be extracted from gloves using a specified solvent that has been selected for its extracting qualities, or because it is representative of solvents used in the particular facility. Alternative solvents may be used, but since their use may result in different values being generated, they must be identified in the procedure data sheet.

This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.


2. Referenced Documents

D1193 Specification for Reagent Water
F50 Practice for Continuous Sizing and Counting of Airborne Particles in Dust-Controlled Areas and Clean Rooms Using Instruments Capable of Detecting Single Sub-Micrometre and Larger Particles
G120 Practice for Determination of Soluble Residual Contamination by Soxhlet Extraction
Air Force T.O. 00-25-203 Contamination Control of Aerospace Facilities
MIL-F-51068F Filters, Particulate (High Efficiency, Fire Resistant)
Fed Spec O-E-00760 Ethyl Alcohol
Fed Std 209E Airborne Particulate Classes for Cleanrooms and Clean Zones
IES-RP-CC005.2 Gloves and Finger Cots Used in Cleanrooms and Other Controlled Environments
Industrial Ventilation, A Manual of Recommended Practice
ISO/DIS 14644-1 Cleanrooms and Associated Controlled Environments, Classification of air cleanliness
ISO/DIS 14644-2 Cleanrooms and Associated Controlled Environments, Specifications for testing and monitoring to prove continued compliance with ISO 14644-1


Index Terms

cleanroom gloves; gloves; non-volatile residue; NVR; ICS Number Code 49.025.99; 71.040.50