Abstract
This test method covers a technique for generating data to characterize the kinetics of the release of outgassing products from spacecraft materials. This technique will determine both the total mass flux evolved by a material when exposed to a vacuum environment and the deposition of this flux on surfaces held at various specified temperatures. The quartz crystal microbalances used in this test method provide a sensitive technique for measuring very small quantities of deposited mass. There are two test methods in this standard: Test Method A and Test Method B. The test apparatus shall consists of four main subsystems: a vacuum chamber, a temperature control system, internal configuration, and a data acquisition system. A test procedure for collecting data and a test method for processing and presenting the collected data are included.
This abstract is a brief summary of the referenced standard. It is informational only and not an official part of the standard; the full text of the standard itself must be referred to for its use and application. ASTM does not give any warranty express or implied or make any representation that the contents of this abstract are accurate, complete or up to date.
1. Scope
1.1 This test method covers a technique for generating data to characterize the kinetics of the release of outgassing products from materials. This technique will determine both the total mass flux evolved by a material when exposed to a vacuum environment and the deposition of this flux on surfaces held at various specified temperatures.
1.2 This test method describes the test apparatus and related operating procedures for evaluating the total mass flux that is evolved from a material being subjected to temperatures that are between 298 and 398K. Pressures external to the sample effusion cell are less than 7 × 10−3 Pa (5 × 10−5 torr). Deposition rates are measured during material outgassing tests. A test procedure for collecting data and a test method for processing and presenting the collected data are included.
1.3 This test method can be used to produce the data necessary to support mathematical models used for the prediction of molecular contaminant generation, migration, and deposition.
1.4 All types of organic, polymeric, and inorganic materials can be tested. These include polymer potting compounds, foams, elastomers, films, tapes, insulations, shrink tubing, adhesives, coatings, fabrics, tie cords, and lubricants.
1.5 There are two test methods in this standard. Test Method A uses standardized specimen and collector temperatures. Test Method B allows the flexibility of user-specified specimen and collector temperatures, material and test geometry, and user-specified QCMs.
1.6 The values stated in SI units are to be regarded as the standard.
1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
2. Referenced Documents
E177 Practice for Use of the Terms Precision and Bias in ASTM Test Methods
E595 Test Method for Total Mass Loss and Collected Volatile Condensable Materials from Outgassing in a Vacuum Environment
IEEE/ASTM SI 10 American National Standard for Use of the International System of Units (SI): The Modern Metric System
MIL-P-27401C Propellant Pressurizing Agent, Nitrogen
Index Terms
contamination control; materials; molecular deposition; outgassing; spacecraft; ICS Number Code 49.025.01