Standards

ASTM C109 / C109M - 07


ASTM C109 / C109M - 07 Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens)


Active Standard ASTM C109 / C109M Developed by Subcommittee: C01.27 |Book of Standards Volume: 04.01

more info 9 pages $ 36.00
more info 9 pages $ 36.00
why redline? 18 pages $ 43.20

Historical(view previous versions of standard) ASTM License Agreement
Translated Standard: Spanish
more info

Description Related Products Find Labs Find Equipment MFR.

ASTM C109 / C109M

Significance and Use

This test method provides a means of determining the compressive strength of hydraulic cement and other mortars and results may be used to determine compliance with specifications. Further, this test method is referenced by numerous other specifications and test methods. Caution must be exercised in using the results of this test method to predict the strength of concretes.

1. Scope

1.1 This test method covers determination of the compressive strength of hydraulic cement mortars, using 2-in. or [50-mm] cube specimens.

Note 1 - Test Method C 349 provides an alternative procedure for this determination (not to be used for acceptance tests).

1.2 This test method covers the application of the test using either inch-pound or SI units. The values stated in either system shall be regarded separately as standard. Within the text, the SI units are shown in brackets. The values stated in each system are not exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with the specification.

1.3 Values in SI units shall be obtained by measurement in SI units or by appropriate conversion, using the Rules for Conversion and Rounding given in Standard IEEE/ASTM SI 10, of measurements made in other units.

This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. ( Fresh hydraulic cementitious mixtures are caustic and may cause chemical burns to skin and tissue upon prolonged exposure.)


2. Referenced Documents

C1005 Specification for Reference Masses and Devices for Determining Mass and Volume for Use in the Physical Testing of Hydraulic Cements
C114 Test Methods for Chemical Analysis of Hydraulic Cement
C1157 Performance Specification for Hydraulic Cement
C1328 Specification for Plastic (Stucco) Cement
C1329 Specification for Mortar Cement
C1437 Test Method for Flow of Hydraulic Cement Mortar
C150 Specification for Portland Cement
C230/C230M Specification for Flow Table for Use in Tests of Hydraulic Cement
C305 Practice for Mechanical Mixing of Hydraulic Cement Pastes and Mortars of Plastic Consistency
C349 Test Method for Compressive Strength of Hydraulic-Cement Mortars (Using Portions of Prisms Broken in Flexure)
C511 Specification for Mixing Rooms, Moist Cabinets, Moist Rooms, and Water Storage Tanks Used in the Testing of Hydraulic Cements and Concretes
C595 Specification for Blended Hydraulic Cements
C618 Specification for Coal Fly Ash and Raw or Calcined Natural Pozzolan for Use in Concrete
C670 Practice for Preparing Precision and Bias Statements for Test Methods for Construction Materials
C778 Specification for Standard Sand
C91 Specification for Masonry Cement
C989 Specification for Ground Granulated Blast-Furnace Slag for Use in Concrete and Mortars
IEEE/ASTM SI 10 Standard for Use of the International System of Units (SI): The Modern Metric System


Index Terms

compressive strength; hydraulic cement mortar; hydraulic cement strength; mortar strength; strength; ICS Number Code 91.100.10


Citing ASTM Standards

[Back to Top]

Standards Tracker

Standards Subscriptions


Users also bought:
C1019
C780
C140