1. Scope
1.1 This performance specification covers hydraulic cements for both general and special applications. There are no restrictions on the composition of the cement or its constituents (See Note 1).
Note 1—There are two related hydraulic cement standards, Specification C 150 for portland cement and Specifications C 595 for blended cements, both of which contain prescriptive and performance requirements
1.2 This performance specification classifies cements based on specific requirements for general use, high early strength, resistance to attack by sulfates, and heat of hydration. Optional requirements are provided for the property of low reactivity with alkali-silica-reactive aggregates.
1.3 For properties where values are given in both SI and inch-pound units, the values in SI units are to be regarded as the standard. Values in SI units shall be obtained by measurement in SI units or by appropriate conversion, using the Rules for Conversion and Rounding given in IEEE/ASTM SI 10, of measurements made in other units.
1.4 The text of this standard refers to notes and footnotes that provide explanatory material. These notes and footnotes (excluding those in tables and figures) are not requirements of the standard.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
2. Referenced Documents
C1012 Test Method for Length Change of Hydraulic-Cement Mortars Exposed to a Sulfate Solution
C1038 Test Method for Expansion of Portland Cement Mortar Bars Stored in Water
C109/C109M Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens)
C114 Test Methods for Chemical Analysis of Hydraulic Cement
C150 Specification for Portland Cement
C151 Test Method for Autoclave Expansion of Portland Cement
C183 Practice for Sampling and the Amount of Testing of Hydraulic Cement
C185 Test Method for Air Content of Hydraulic Cement Mortar
C186 Test Method for Heat of Hydration of Hydraulic Cement
C188 Test Method for Density of Hydraulic Cement
C191 Test Method for Time of Setting of Hydraulic Cement by Vicat Needle
C204 Test Method for Fineness of Hydraulic Cement by Air Permeability Apparatus
C219 Terminology Relating to Hydraulic Cement
C226 Specification for Air-Entraining Additions for Use in the Manufacture of Air-Entraining Hydraulic Cement
C227 Test Method for Potential Alkali Reactivity of Cement-Aggregate Combinations (Mortar-Bar Method)
C311 Test Methods for Sampling and Testing Fly Ash or Natural Pozzolans for Use as a Mineral Admixture in Portland-Cement Concrete
C430 Test Method for Fineness of Hydraulic Cement by the 45-m (No. 325) Sieve
C441 Test Method for Effectiveness of Pozzolans or Ground Blast-Furnace Slag in Preventing Excessive Expansion of Concrete Due to the Alkali-Silica Reaction
C451 Test Method for Early Stiffening of Hydraulic Cement (Paste Method)
C465 Specification for Processing Additions for Use in the Manufacture of Hydraulic Cements
C595 Specifications for Blended Hydraulic Cements
C688 Specification for Functional Additions for Use in Hydraulic Cements
IEEE/ASTM SI 10 Standard for Use of the International System of Units (SI): the Modern Metric System
Index Terms
blended hydraulic cement; hydraulic cement; performance; Granular blast furnace; Hydraulic cement concrete--specifications; Performance--building materials/applications (specifications); Pozzolans--specifications; Silica fume--specifications; Slag; ICS Number Code 91.100.10
DOI: 10.1520/C1157-03

ASTM International is a member of CrossRef.
Citing ASTM Standards
[Back to Top]