ASTM D5317-98(2003)e1

Standard Test Method for Determination of Chlorinated Organic Acid Compounds in Water by Gas Chromatography with an Electron Capture Detector

Standard Test Method for Determination of Chlorinated Organic Acid Compounds in Water by Gas Chromatography with an Electron Capture Detector D5317-98R03E01 ASTM|D5317-98R03E01|en-US Standard Test Method for Determination of Chlorinated Organic Acid Compounds in Water by Gas Chromatography with an Electron Capture Detector Standard new BOS Vol. 11.02 Committee D19
$ 83.00 In stock

Significance and Use

Chlorinated phenoxyacid herbicides, and other organic acids are used extensively for weed control. Esters and salts of 2,4-D and silvex have been used as aquatic herbicides in lakes, streams, and irrigation canals. Phenoxy acid herbicides can be toxic even at low concentrations. For example, the 96 h, TLm for silvex is 2.4 mg/L for bluegills (1)9 . These reasons make apparent the need for a standard test method for such compounds in water.

Scope

1.1 This test method covers a gas chromatographic procedure for the quantitative determination of selected chlorinated acids and other acidic herbicides in water. Similar chemicals may also be determined by this test method, but it is the user's responsibility to verify the applicability of this test method to any compounds not listed in this scope. The acid form of the following compounds were interlaboratory tested using this test method, and the results were found acceptable:

AnalyteChemical Abstract Services Registry Number
Bentazon25057-89-0
2,4-D94-75-7
2,4-DB94-82-6
DCPA acid metabolites 2
Dicamba1918-00-9
3,5-Dichlorobenzoic acid51-36-5
Dichlorprop120-36-5
5-Hydroxydicamba7600-50-2
Pentachlorophenol (PCP)87-86-5
Picloram1918-02-1
2,4,5-T93-76-5
2,4,5-TP (Silvex)93-72-1

1.2 This test method may be applicable to the determination of salts and esters of analyte compounds. The form of each acid is not distinguished by this test method. Results are calculated and reported for each listed analyte as the total free acid.

1.3 This test method has been validated in an interlaboratory test for reagent water and finished tap water. The analyst should recognize that precision and bias reported in Section 18 may not be applicable to other waters.

1.4 This test method is restricted to use by or under the supervision of analysts experienced in the use of gas chromatography (GC) and in the interpretation of gas chromatograms. Each analyst must demonstrate the ability to generate acceptable results with this test method using the procedure described in 19.3. It is the user's responsibility to ensure the validity of this test method for waters of untested matrices.

1.5 Analytes that are not separated chromatographically, that is, which have very similar retention times, cannot be individually identified and measured in the same calibration mixture or water sample unless an alternate technique for identification and quantitation exists (16.6, 16.7, and 16.8).

1.6 When this test method is used to analyze unfamiliar samples for any or all of the analytes given in 1.1, analyte identifications must be confirmed by at least one additional qualitative technique.

1.7 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.

1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific warning statements, see Sections 6 ,8 ,9 and 10.