1. Scope
1.1 This test method covers the determination of the fineness of hydraulic cement by means of the 45-μm (No. 325) sieve.
1.2 The values stated in SI units are to be regarded as the standard. The inch-pound equivalents of SI units may be approximate.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
2. Referenced Documents (purchase separately)
The documents listed below are referenced within the subject standard but are not provided as part of the standard.
ASTM Standards
E11 Specification for Woven Wire Test Sieve Cloth and Test Sieves
E161 Specification for Precision Electroformed Sieves
E177 Practice for Use of the Terms Precision and Bias in ASTM Test Methods
Index Terms
fineness of hydraulic cement; Portland cement; Sieve analysis--building materials; Fineness--hydraulic cement (blended/portland); Hydraulic cement concrete
DOI: 10.1520/C0430-96R03
ASTM International is a member of CrossRef.
Citing ASTM Standards
[Back to Top]