Standard Historical Last Updated: Oct 12, 2011 Track Document
ASTM C169-92(2005)

Standard Test Methods for Chemical Analysis of Soda-Lime and Borosilicate Glass

Standard Test Methods for Chemical Analysis of Soda-Lime and Borosilicate Glass C0169-92R05 ASTM|C0169-92R05|en-US Standard Test Methods for Chemical Analysis of Soda-Lime and Borosilicate Glass Standard new BOS Vol. 15.02 Committee C14
$ 108.00 In stock

Significance and Use

These test methods can be used to ensure that the chemical composition of the glass meets the compositional specification required for the finished glass product.

These test methods do not preclude the use of other methods that yield results within permissible variations. In any case, the analyst should verify the procedure and technique employed by means of a National Institute of Standards and Technology (NIST) standard reference material having a component comparable with that of the material under test. A list of standard reference materials is given in the NIST Special Publication 260,3 current edition.

Typical examples of products manufactured using soda-lime silicate glass are containers, tableware, and flat glass.

Typical examples of products manufactured using borosilicate glass are bakeware, labware, and fiberglass.

Typical examples of products manufactured using fluoride opal glass are containers, tableware, and decorative glassware.

Scope

1.1 These test methods cover the quantitative chemical analysis of soda-lime and borosilicate glass compositions for both referee and routine analysis. This would be for the usual constituents present in glasses of the following types: (1) soda-lime silicate glass, (2) soda-lime fluoride opal glass, and (3) borosilicate glass. The following common oxides, when present in concentrations greater than indicated, are known to interfere with some of the determinations in this method: 2 % barium oxide (BaO), 0.2 % phosphorous pentoxide (P2O5), 0.05 % zinc oxide (ZnO), 0.05 % antimony oxide (Sb2O3), 0.05 % lead oxide (PbO).

1.2 The analytical procedures, divided into two general groups, those for referee analysis, and those for routine analysis, appear in the following order:

This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Price:
Contact Sales
Related
Reprints and Permissions
Reprints and copyright permissions can be requested through the
Copyright Clearance Center
Details
Book of Standards Volume: 15.02
Developed by Subcommittee: C14.02
Pages: 23
DOI: 10.1520/C0169-92R05
ICS Code: 81.040.10