1. Scope
1.1 This test method covers the effects of repeated insertion and withdrawal of separable electrical connectors which are harmful to the electrical performance of the connector.
1.2 This test method is limited to electrical connectors designed for use in applications where the current through any one connection in the connector does not exceed 5 A, and where the connector may be separated a number of times during the life of the connector.
1.3 This test method is limited to electrical connectors intended for use in air ambients where the operating temperature is less than 65°C.
1.4 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
2. Referenced Documents (purchase separately)
The documents listed below are referenced within the subject standard but are not provided as part of the standard.
ASTM Standards
B539 Test Methods for Measuring Resistance of Electrical Connections (Static Contacts)
Military Standard
MIL-STD-1344A Test Methods for Electrical Connectors
Keywords
contact resistance; electrical connectors; electrical contacts; temperature and humidity cycling test; wear; wear tracks; Accelerated aging/testing--electrical heating/contact materials; Degradation--electrical contact materials; Durability--building materials/applications; Electrical resistance/resistivity--electrical contact materials; Performance--electrical/electronic systems/applications; Temperature tests--electrical contact materials; Compact resistance; Cyclic temperature-humidity test; Electrical connectors; Electrical contact materials; Electrical properties; Humidity; Insertion/withdrawal cycles; Mechanical properties; Temperature-humidity cyclic test; Vibration test; Wear testing ;
ICS Code
DOI: 10.1520/B0794-97
ASTM International is a member of CrossRef.
Citing ASTM Standards
[Back to Top]