ASTM B490-09

    Standard Practice for Micrometer Bend Test for Ductility of Electrodeposits

    SUPERSEDED (see Active link, below)


      Format Pages Price  
    PDF 2 $45.60   ADD TO CART


    1. Scope

    1.1 This practice describes a procedure for measuring the ductility of electrodeposited foils.

    1.2 This practice is suitable only for the evaluation of electrodeposits having low ductility.

    1.3 The obtained ductility values must only be considered semi-quantitative because this test has a significant operator dependence.

    1.4 This practice is best used for in-house process control where measurements are always made by the same operator. A change in ductility value can be used as an indication of possible changes in the electroplating solution.

    1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

    1.6 This standard does not purport to address the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.


    2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.

    ASTM Standards

    B456 Specification for Electrodeposited Coatings of Copper Plus Nickel Plus Chromium and Nickel Plus Chromium


    ICS Code

    ICS Number Code 17.040.20 (Properties of surfaces); 25.220.40 (Metallic coatings)

    UNSPSC Code

    UNSPSC Code


    DOI: 10.1520/B0490-09

    ASTM International is a member of CrossRef.


    Citing ASTM Standards
    Back to Top