Standard Historical Last Updated: Nov 15, 2016 Track Document
ASTM B111/B111M-11

Standard Specification for Copper and Copper-Alloy Seamless Condenser Tubes and Ferrule Stock

Standard Specification for Copper and Copper-Alloy Seamless Condenser Tubes and Ferrule Stock B0111_B0111M-11 ASTM|B0111_B0111M-11|en-US Standard Specification for Copper and Copper-Alloy Seamless Condenser Tubes and Ferrule Stock Standard new BOS Vol. 02.01 Committee B05
$ 83.00 In stock

Abstract

This specification establishes the requirements for seamless tube and ferrule stock of copper and various copper alloys of a specified range of diameters, for use in surface condensers, evaporators, and heat exchangers. The specified coppers and copper alloys are UNS No. C10100, C10200, C10300, C10800, C12000, C12200, C14200, C19200, C23000, C28000, C44300, C44400, C44500, C60800, C61300, C61400, C68700, C70400, C70600, C70620, C71000, C71500, C71520, C71640, and C72200. The product shall be produced by processes such as casting, extrusion, drawing, annealing, straightening, trimming, and other processes which may produce a seamless tube in the specified condition. The coppers and copper alloys shall be specifically furnished in any one of the following tempers: annealed, light-drawn, hard-drawn, or hard drawn and end annealed. Tubes for ferrule stock shall be annealed sufficiently to be fully crystallized. Some tubes are suggested to be subjected to a stress-relieving thermal treatment subsequent to straightening. The products shall be subjected to expansion, flattening, and residual stress tests. The tensile and expansion requirements for the products are specified in accordance with the temper designation. The products shall also be subjected to mercurous nitrate, ammonia vapor, Eddy-current, hydrostatic, and pneumatic tests.

Scope

1.1 This specification establishes the requirements for seamless tube and ferrule stock of copper and various copper alloys up to 31/8 in. [80 mm] inclusive, in diameter, for use in surface condensers, evaporators, and heat exchangers. The following coppers and copper alloys are specified: (WarningMercury is a definite health hazard in use and disposal. (See 12.1.))

Copper or
Copper
Alloy
UNS No.
Previously
Used
Designation
Description
C10100OFEOxygen-free electronic
C10200OFAOxygen-free without residual deoxidants
C10300. . .Oxygen-free, extra low phosphorus
C10800. . .Oxygen-free, low phosphorus
C12000DLPAPhosphorized, low residual phosphorus
C12200DHPAPhosphorized, high residual phosphorus
C14200DPAAPhosphorized, arsenical
C19200. . .Phosphorized, 1 % iron
C23000. . .Red Brass
C28000. . .Muntz Metal
C44300. . .Admiralty Metals, B, C, and D
C44400
C44500
C60800 . . . Aluminum Bronze
C61300. . .. . .
C61400. . .Aluminum Bronze, D
C68700. . .Aluminum Brass, B
C70400. . .95-5 Copper-Nickel
C70600. . .90-10 Copper-Nickel
C70620. . .90-10 Copper-NickelWelding Grade
C71000. . .80-20 Copper-Nickel
C71500. . .70-30 Copper-Nickel
C71520. . .70-30 Copper-NickelWelding Grade
C71640. . .Copper-nickel-iron-manganese
C72200. . .. . .

A Designations listed in Classification B224.

1.2 UnitsThe values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact    equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.

1.3 The following safety hazards caveat pertains only to the test methods portion, Section 19, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Price:
Contact Sales
Related
Reprints and Permissions
Reprints and copyright permissions can be requested through the
Copyright Clearance Center
Details
Book of Standards Volume: 02.01
Developed by Subcommittee: B05.04
Pages: 12
DOI: 10.1520/B0111_B0111M-11
ICS Code: 23.040.15